Q
Can you show me details of multi-level collection device for wax collection (heated tubes from graphite box to collector also ?)
A
Yes, DMF will offer multi-level collection device for wax collection (heated tubes from graphite box to collector.
-
Q
The hot water temperature regulation/ heater is also included in control unit of furnace or separate ?
A
The hot water temperature regulation is set separately, while the heater is included in control unit of furnace.
-
Q
Min and max negative pressure for Ar dewaxing ?
A
Negative Pressure for Ar Dewaxing Max= 35mbar Min=5mbar
-
Q
Max Ar pressure for sintering with Argon atmosphere (without diffusion pump) ? 1000 mbar pressure OK ?
A
∴Max Ar pressure for sintering with Ar (without diffusion pump) =40mbar ∴1000 mbar pressure is availabe but will increase at least 10% equipment cost.
-
Q
If sintering in Ar atmosphere, all the furnace is also under Ar atmosphere at same pressure ?
A
It can be regarded as the same pressure although the pressure near the vacuum access is a bit lower which can be ignored.
-
Q
Floor footprint / Overall dimensions of furnace ?
A
DMF will offer the layput as per requirment in details.
-
Q
Requirements (cooling water/compressed air....) ?
A
Cooling Water: 0.1~0.25MPa, diameter 2", 6~8M3/h
-
Q
Calitatea Ar este necesară?
A
Puritate Argon: 99.999%
-
Q
În ceea ce privește achiziția / logistica, ne-ați putea anunța care este codul HS pentru echipamente (poate că va fi mai mult de unul)? Dorim ca aceste informații să verifice care sunt taxele potențiale aplicate pentru importul mașinii.
A
Cod HS (cod armonizat cu 10 cifre): 8514109000
-
Q
Ați putea să-mi spuneți despre procedura și măsurile de precauție atunci când folosim gazul H2 la încălzire? Ar fi util să ne spuneți diferența față de cazul gazului N2.
A
Da, vă rugăm să verificați manualul corespunzător. Este scris atât în engleză, cât și în chineză